Fire Safety Science · 1989 · 20 citations · 4 references
PlanningTheatre StudiesEmergency ManagementEvacuation PlanningExperimental TheatreEvacuation DesignEvacuation TimingHuman Behavior In FireEvacuationExit LayoutExit Route ChoiceExit Selection BehaviorHuman Behavior In EvacuationOrder Of EvacuationSafety MarginSeat Position Effects
The pattern of movement to exits in two lecture theatres during a monitored evacuation is examined. The research study focuses on exit choice behaviour: the distance, direction and time taken to leave a setting in which there is an entrance and emergency fire exit. The front (F) lecture theatre studied has both of its exits at the Dack. In contrast, a nearDy (R) lecture theatre, has the same design except that the entrance is in one corner at the back and fire exit towards the front. In the F theatre, 55% of the 56 people left via the main entrance, 45% via the fire exit. 88% of the individuals monitored left within 2.5 minutes. The pattern of movement, distance covered, exit used and time to leave by the different exits in the F theatre, were statistically analysed in relation to initial seat position. Under instructions from the lecturer everyone in the R theatre left Dy the fire exit. 70% of the total of 77 people left within 2.5 minutes. The exit choice Dehaviour is discussed in relation to the 2.5 minutes safety margin, the lecture theatre layout, different exit locations, verDal instruction from the lecturers and normal entry to and egress from the theatres.
4
Jonathan D. Sime · Environment and Behavior · 1985 · 209 citations
Perceived Time Available: The Margin Of Safety In Fires
Jonathan D. Sime · Fire Safety Science · 1986 · 32 citations · Full text