Normalized and Average Current Distributions on Unevenly Spaced Patterns

Alan C. West, M. Matlosz, D. Landolt

Journal of The Electrochemical Society · 1991 · 26 citations · 3 references

Concepts

Abstract

Spatial variations in electrochemical etch rate are predicted for an unevenly spaced pattern of lines. Two models, based on primary current distribution calculations, are presented. One model is used to estimate the normalized current distribution on an individual line of the pattern. The results indicate that the model, which accounts only for the placement of the nearest neighbor lines while ignoring the other geometric details, predicts well the primary current distribution. The other model, based on boundary integral equations, is used for an estimation of the distribution from line to line of the average current densities. The results, which agree with experiment, are insensitive to the details of the normalized current distributions that are assumed on the individual lines in the pattern.

References

3