The Analyst · 1998 · 25 citations · 12 references
PharmacyPharmaceutical AnalysisPharmaceuticsAnalytical ToxicologyBiopharmaceuticsChromatographic AnalysisBioanalytical Method ValidationExtraction TechniquesVeterinary Drug ResiduesDrug Residue DetectionMatrix Solid-phase DispersionPharmaceutical ResiduesPhase DispersionRecovery Of Pharmaceutical CompoundsResidue Detection LimitsReversed-phase Solid-phase ExtractionVeterinary Drug Residue Limits
The aim of this study was to develop a multi-residue method for the analysis of penicillins in animal tissue. Matrix solid phase dispersion (MSPD) was employed to extract the residues and the extracts were then cleaned-up by C18 solid phase extraction (SPE). Pre-column derivatisation using acetic anhydride and 1,2,4-triazole in the presence of mercuric chloride was employed to allow detection in 325 nm. Gradient elution was required to elute amoxicillin, ampicillin, penicillin G, cloxacillin and dicloxacillin derivatives from a C18 reversed phase column using phosphate buffer-acetonitrile mobile phase. The developed method had a limit of detection of 20 ng g-1 and had recoveries in the range 40-90% for the 5 drugs in samples fortified at 40 and 200 ng g-1; the maximum residue limits (MRLs) for these drugs were in the range of 50-300 ng g-1 (ppb).
12
Krystyna Tyczkowska, Robert D. Voyksner, Rolf Straub et al. · Journal of AOAC International · 1994 · 44 citations