Aerosol and Air Quality Research · 2011 · 28 citations · 45 references
Public HealthEnvironmental SciencesMicrobiologyAir PollutionAtmospheric ChemistryEnvironmental HealthAir PollutantsAir Pollution MeasurementAir QualityAir SamplingIndoor Air PollutionParticulate MatterAirborne Particle MonitoringAirborne ParticlesAirborne Particulate AnalysisEndotoxin DetectionEndotoxin QuantificationHome Microbial ExposureIndoor Air Microbial AssessmentIndoor Air Quality Measurement
Objectives: Concentrations of microbial cell wall components such as endotoxin and β-D-glucan in airborne submicrometer particle size fraction (PM1, defined as particles with median aerodynamic diameter, da ≤ 1 μm) have not been well characterized. In this study, airborne concentrations of endotoxin and β-D-glucan among different size fractions were quantified in two distinctly different environments: farms and homes. Effect of microbial source (farm type for farms and mold damage for homes) on size-fractionated concentrations was investigated. Methods: Airborne endotoxin and β-D-glucan were collected on 7 farms and 184 suburban homes using NIOSH two-stage sampler, a cyclone air sampler that fractionates airborne particles into three size fractions: ≤ 1 μm, 1–1.8 μm and ≥ 1.8 μm. Results: Geometric means (geometric standard deviations) of airborne total endotoxin concentration on farms and in homes were 1.20 × 104 (7.57) EU/m3 and 2.67 (3.82) EU/m3, respectively. Similar values of airborne total β-D-glucan concentrations were 1.80 × 103 (152.88) ng/m3 and 1.91 (2.83) ng/m3, respectively. Relative proportions of PM1 endotoxin, however, were significantly higher (p < 0.001) in home samples (7.9%) than in farm samples (0.3%). Likewise, the proportion of PM1 β-D-glucan was significantly higher (p < 0.001) in homes (28.2% vs. 2.3%). Farm type significantly influenced concentrations of PM1 β-D-glucan (p < 0.05) and total β-D-glucan (p < 0.001). Conclusions: The results of this study demonstrate higher proportions of PM1 endotoxin and β-D-glucan in homes compared to farms. These data further emphasize the importance of conducting size-selective air sampling for microbial exposure assessment in homes.
45
Fungal Fragments as Indoor Air Biocontaminants
Rafał L. Górny, Tiina Reponen, Klaus Willeke et al. · Applied and Environmental Microbiology · 2002 · 396 citations · Full text
Kristian Fog Nielsen, George E. Holm, L.P. Uttrup et al. · International Biodeterioration & Biodegradation · 2004 · 307 citations