Review of Scientific Instruments · 2010 · 31 citations · 7 references
Natural SciencesPhysicsPlasma PhysicsSpectroscopic AnalysisSpectroscopyMagnetized PlasmaPlasma DiagnosticsCurrent DensityCurrent Density ReconstructionMagnetic Field MeasurementsMagnetic Pitch AngleMotional Stark Effect DiagnosticsSafety FactorStark Effect MeasurementsSystematic Errors
A high-precision spectral motional Stark effect (MSE) diagnostic provides internal magnetic field measurements for Madison Symmetric Torus (MST) plasmas. Currently, MST uses two spatial views--on the magnetic axis and on the midminor (off-axis) radius, the latter added recently. A new analysis scheme has been developed to infer both the pitch angle and the magnitude of the magnetic field from MSE spectra. Systematic errors are reduced by using atomic data from atomic data and analysis structure in the fit. Reconstructed current density and safety factor profiles are more strongly and globally constrained with the addition of the off-axis radius measurement than with the on-axis one only.
7
R. N. Dexter, D. W. Kerst, T. W. Lovell et al. · Fusion Technology · 1991 · 320 citations
Beam emission spectroscopy as a comprehensive plasma diagnostic tool
W. Mandl, R. C. Wolf, M. G. von Hellermann et al. · Plasma Physics and Controlled Fusion · 1993 · 119 citations
Equilibrium reconstruction in the Madison Symmetric Torus reversed field pinch
J. K. Anderson, C. B. Forest, T. M. Biewer et al. · Nuclear Fusion · 2003 · 68 citations