Review of Scientific Instruments · 2001 · 217 citations · 5 references
Natural SciencesBiomedical EngineeringPhysicsBiomedical OpticsBiophotonicsOpticsConfocal MicroscopyInfrared InstrumentationInfrared SpectroscopyLight MicroscopyOptical AberrationsOptical ImagingDiffraction TheoryDiffraction-limited ImagingDiffraction-limited ResolutionFull Width At Half MaximumInfrared MicroscopyInfrared MicrospectroscopyMicrospectroscopyResolving Power
Diffraction-limited resolution is achieved when instrument apertures match the wavelength, but commercial microspectrometers, though well corrected for aberrations, suffer chromatic aberrations from standard specimen substrates. This study investigates the practical spatial resolution limits of infrared microspectroscopy imposed by diffraction and optical aberrations. High-brightness synchrotron radiation was used as a diffraction-limited infrared point source, and a confocal optical arrangement and diffraction calculations were employed to analyze image contrast and chromatic aberrations, with correction methods described. Measured resolving power agreed with diffraction theory, showing about a 30 % improvement with a confocal setup and a full width at half maximum of roughly λ/2.
The spatial resolution for infrared microspectroscopy is investigated to determine the practical limits imposed by diffraction or optical aberrations. Quantitative results are obtained using high brightness synchrotron radiation, which serves as a diffraction-limited infrared “point source” for the microscope. The measured resolving power is in good agreement with diffraction theory, including a ∼ 30% improvement for a confocal optical arrangement. The diffraction calculation also shows how the confocal setup leads to better image contrast. The full width at half maximum of the instrument’s resolution pattern is approximately λ/2 for this arrangement. One achieves this diffraction limit when the instrument’s apertures define a region having dimensions equal to the wavelength of interest. While commercial microspectrometers are well corrected for optical aberrations (allowing diffraction-limited results), the standard substrates used for supporting specimens introduce chromatic aberrations. An analysis of this aberration is also presented, and correction methods described.
5
Infrared synchrotron radiation from electron storage rings
William Duncan, Gwyn Williams · Applied Optics · 1983 · 225 citations
Natural Sciences, Physics, Optics +11
Infrared synchrotron radiation programs at the National Synchrotron Light Source
G. L. Carr, Philippe Dumas, C. J. Hirschmug et al. · Il Nuovo Cimento D · 1998 · 40 citations