Journal of Biomedical Materials Research Part A · 2008 · 112 citations · 35 references
Natural SciencesBiomedical EngineeringImmunologyBiocompatibilityBiomaterialsInflammationBiomaterial CharacterizationExtracellular MatrixImplantable BiomaterialsPolymeric BiomaterialsSurface BiocompatibilityWound Healing ResponseAcute Inflammatory ResponseAdherent Cell CultureBiomaterial-macrophage InteractionsExtracellular Matrix ProductionExtracellular Polymeric MatrixPolyethylene TerephthalatePolymeric Implant MaterialsSynthetic Polymers
The role of lymphocytes in the biological response to synthetic polymers is poorly understood despite the transient appearance of lymphocytes at the biomaterial implant site. To investigate cytokines, chemokines, and extracellular matrix (ECM) proteins produced by lymphocytes and macrophages in response to biomaterial surfaces, human peripheral blood monocytes and lymphocytes were co-cultured on polyethylene terephthalate (PET)-based material surfaces displaying distinct hydrophobic, hydrophilic/neutral, hydrophilic/anionic, and hydrophilic/cationic chemistries. Antibody array screening showed the majority of detected proteins are inflammatory mediators that guide the early inflammatory phases of wound healing. Proteomic ELISA quantification and adherent cell analysis were performed after 3, 7, and 10 days of culture. IL-2 and IFN-gamma were not detected in any co-cultures suggesting lack of lymphocyte activation. The hydrophilic/neutral surfaces increased IL-8 relative to the hydrophobic PET surface (p < 0.05). The hydrophilic/anionic surfaces promoted increased TNF-alpha over hydrophobic and cationic surfaces and increased MIP-1beta compared to hydrophobic surfaces (p < 0.05). Since enhanced macrophage fusion was observed on hydrophilic/anionic surfaces, the production of these cytokines likely plays an important role in the fusion process. The hydrophilic/cationic surface promoted IL-10 production and increased matrix metalloproteinase (MMP)-9/tissue inhibitor of MMP (TIMP) relative to hydrophilic/neutral and anionic surfaces (p < 0.05). These results suggest hydrophilic/neutral and anionic surfaces promote pro-inflammatory responses and reduced degradation of the ECM, whereas the hydrophilic/cationic surfaces induce an anti-inflammatory response and greater MMP-9/TIMP with an enhanced potential for ECM breakdown. The study also underscores the usefulness of protein arrays in assessing the role of soluble mediators in the inflammatory response to biomaterials.
35
Biological Responses to Materials
James Anderson · Annual Review of Materials Research · 2001 · 1.5K citations
B7-H4, a Molecule of the B7 Family, Negatively Regulates T Cell Immunity
Gabriel Sica, In-Hak Choi, Gefeng Zhu et al. · Immunity · 2003 · 696 citations · Full text