Optics Letters · 2011 · 41 citations · 3 references
EngineeringOphthalmologyMicrofabricationElastic Silicone MembraneOptic DesignIntegrated ActuationRing-shaped PiezoelectricBiomedical EngineeringVariable Aperture Stop
In this Letter we report on the fabrication and testing of an extremely thin variable aperture stop based on the design of a single chamber adaptive membrane lens with integrated actuation. The aperture consists of a ring-shaped piezoelectric bending actuator with an elastic silicone membrane in the center. The formed cavity is filled with a nontransparent fluid and sealed with a glass platelet. In a voltage range up to 80 V, an opening of the aperture of 4.55 mm in diameter is obtained. The transmission in comparison to a standard mechanical aperture stop is maximum 6% lower.
3
Yu Hongbin, Guangya Zhou, Chau Fook Siong et al. · Optics Letters · 2008 · 72 citations
Polydimethylsiloxane-based Optofluidic Technology, Engineering, Ophthalmology +12
An Optofluidic Concept for a Tunable Micro-iris
Philipp Müller, Nils Spengler, Hans Zappe et al. · Journal of Microelectromechanical Systems · 2010 · 46 citations