International Journal of Fluid Machinery and Systems · 2010 · 20 citations · 2 references
EngineeringWater Resources ManagementFluid DynamicsHydraulic EngineeringHydraulicsCavitationHydraulic MachineryHydraulic Power SystemsHydraulic SystemsHydropower EngineeringWater Power SystemsCavitation NumberHydraulic PowerHydraulic VibrationNumerical SimulationSelf-excited OscillationsSelf-excited VibrationSelf-oscillationSurge
Based on the one-dimensional stability analysis, the self-excited oscillation in hydraulic power generating systems was studied by a simple experiment and numerical simulation. It was shown that a cavity in a conical diffuser can cause surge. With the diffuser, a high amplitude and low frequency oscillation occurs at low cavitation number. This oscillation was not observed with the straight pipe. It was confirmed that the diffuser effect of the draft tube can be the cause of the full load surge in hydraulic power system. Numerical results were also analyzed to check the validity of the one-dimensional stability analysis.
2
One-Dimensional Analysis of Full Load Draft Tube Surge
Changkun Chen, Christophe Nicolet, Koichi Yonezawa et al. · Journal of Fluids Engineering · 2008 · 76 citations · Full text