EngineeringChemical EngineeringChemistryAnalytical ChemistryElemental AnalysisMetallurgyAcidity AnalysisElemental Composition AnalysisFerrous MetallurgyProcess Analytical ChemistryRedox TitrationsAcidity CharacterizationConcentrationFerric Hydroxide PrecipitationFree AcidityIron(iii) TitrationsMethyl Red TestProcess Injection AnalysisSample Introduction Systems
A new software-controlled volume-based system for sample introduction in process flow injection analysis was developed. By using a multi-syringe burette coupled with one or two additional commutation valves, the multi-commuted injection of precise sample volumes was accomplished. Characteristics and performance of the injection system were studied by injecting an indicator in a buffered carrier. Three configurations were implemented in order to achieve two different tasks: the single injection of a sample in a two- or three-channels manifold, and the dual injection into different streams. The two channel flow system using the single injection was applied to the determination of free acidity in diluted samples containing high levels of iron(III), by employing the single point titration methodology. The precipitation of ferric hydroxide was prevented using the ammonium and sodium salts of oxalate and acetate as buffer titrant. Methyl Red was employed as indicator. The procedure allows determination of acid concentration in solutions with a Fe(III)/H+ molar ratio up to 0.2. Samples with higher Fe(III)/H+ molar ratios were spiked with a known strong acid at dilution. The three-channel configuration was applied to the determination of ferric ions, using, as reagent, a merging mixture of sulfuric acid and potassium thiocyanate. The double injection system was implemented in series in a single (three-channel) manifold in such a way that a different injection volume and a changed reagent were used for each analyte. It was applied to the separated or sequential determination of free acidity and ferric ions. In this configuration, iron(III) was determined using 0.5-0.7% (w/v) sodium salicylate solution as reagent. The systems can operate at up to 100, 84 and 78 injections per hour, respectively. Determinations on synthetic and process samples compared well with the reference values and procedures. Recoveries of 95-102% with a maximum RSD value of 5.4% were found for acidity. The respective values obtained for iron determinations were 96-105% and 4.3%.
6
Flow techniques in water analysis
Vı́ctor Cerdà, José Manuel Estela, R. Forteza et al. · Talanta · 1999 · 242 citations
Natural Resources, Hydrology, Water Resources Management +11
A robust multisyringe system for process flow analysis
Fernando Albertús, A. Cladera, Vı́ctor Cerdà et al. · The Analyst · 1999 · 68 citations
Patrícia Benedini Martelli, Boaventura F. Reis, Eloisa A.M. Kronka et al. · Analytica Chimica Acta · 1995 · 54 citations
Thomas P. Lynch, Nicholas J. Kernoghan, John N. Wilson · The Analyst · 1984 · 45 citations