Publication | Closed Access
High Detectivity Uncooled Thermal Detectors With Resonant Cavity Coupled Absorption in the Long-Wave Infrared
17
Citations
16
References
2013
Year
Optical MaterialsEngineeringThermal SensingAbsorption SpectroscopyThermal RadiationSpectral SelectivityOptical PropertiesElectrical ReadoutLong-wave InfraredInfrared OpticInstrumentationPhotonicsElectrical EngineeringPhysicsPeak DetectivityInfrared TechnologyInfrared SensingThermal PhysicsRadiometryOptical SensorsInfrared SensorNatural SciencesSpectroscopyApplied PhysicsThermal SensorInfrared Systems
We describe uncooled thermal detectors with a peak detectivity of at least 3 ×10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">9</sup> cm √{Hz}/W with spectrally selective absorption in the long-wave infrared. The spectral selectivity in absorption is achieved through resonant cavity coupling of a thin metal film with a low-order air-gap optical cavity. The electrical readout uses thermoelectric thin films with a Johnson noise limited performance. The detectors are of multiple sizes but those with 100- μm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> area have time constants of 58 ms and thermal conductances of 2.3 ×10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-7</sup> W/K.