Optics Express · 2014 · 31 citations · 6 references
Natural SciencesPhysicsOptical AstronomyOpticsOrthographic ProjectionAstigmatism CorrectionFourier OpticsHolographyInterferometryOptical AberrationsSpherical AberrationAberration CompensationAberration CorrectionsAberration MeasurementDynamic RangeOcular Aberration CorrectionOptical InterferometersSpherical Aberration CorrectionZernike Polynomials
In off-axis subapertures of most aspheres, astigmatism and coma dominate the aberrations with approximately quadratic and linear increase as the off-axis distance increases. A pair of counter-rotating Zernike plates is proposed to generate variable amount of Zernike terms Z4 and Z6, correcting most of the astigmatism and coma for subapertures located at different positions on surfaces of various aspheric shapes. The residual subaperture aberrations are then reduced within the vertical dynamic range of measurement of the interferometer. The plates are fabricated with computer generated holograms and the experimental results show the variable aberration correction effect without ghost fringes. The same plates are reconfigurable by counter-rotating to enable near-null test of various aspheres flexibly.
6
Experimental study on subaperture testing with iterative stitching algorithm
Shanyong Chen, Shengyi Li, Yifan Dai et al. · Optics Express · 2008 · 44 citations · Full text