Journal of Microelectromechanical Systems · 2014 · 30 citations · 35 references
EngineeringMaterials EngineeringMaterials ScienceMicroelectromechanical SystemsMicrofabricationSensorsMechanical MeasurementMechanical SensorsMicroelectromechanical SensorsSensor MaterialsStrain MeasurementStrain SensorsMagnetoelastic CouplingMagnetoelastic SensorsMetglasResonant FrequencyResonant SensorsResonant Strain SensorsWireless SensingWireless Strain Sensors
This paper describes resonant wireless strain sensors fabricated from magnetoelastic alloys. The transduction mechanism is the ΔE effect-the change in stiffness of magnetoelastic materials with applied strain or magnetic field. This is measured as a shift in the resonant frequency and is detected wirelessly using pick-up coils utilizing the magnetoelastic coupling of these materials. The sensors are fabricated from a 28-μm-thick foil of Metglas 2826 MB (Fe <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">40</sub> Ni <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">38</sub> Mo <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sub> B <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">18</sub> ), a ferromagnetic magnetoelastic alloy, using microelectrodischarge machining. Two sensor types are described-single and differential. The single sensor has an active area of 7 × 2 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> , excluding the anchors. At 23°C, it operates at a resonant frequency of 230.8 kHz and has a sensitivity of 13 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ppm/mstrain; the dynamic range is 0.05-1.05 mstrain. The differential sensor includes a strain independent reference resonator of area 2 × 0.5 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> in addition to a sensing element of area 2.5 × 0.5 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> that is divided into two segments. The sensor resonance is at 266.4 kHz and reference resonance is at 492.75 kHz. The differential sensor provides a dynamic range for 0-1.85 mstrain with a sensitivity of 12.5 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ppm/mstrain at 23°C. The reference resonator of the differential sensor is used to compensate for the temperature dependence of the Young's modulus of Metglas 2826 MB, which is experimentally estimated to be -524 ppm/°C. For an increment of 35°C, uncompensated sensors exhibit a resonant frequency shift of up to 42% of the dynamic range for the single sensor and 30% of the dynamic range of the differential sensor, underscoring the necessity of temperature compensation. The geometry of both types of sensors can be modified to accommodate a variety of sensitivity and dynamic range requirements.
35
Introduction to magnetic materials
Materials Today · 2009 · 5.6K citations · Full text
Demagnetizing factors for rectangular prisms
D.-X. Chen, Enric Pardo, Alvaro Sanchez · IEEE Transactions on Magnetics · 2005 · 158 citations