Effect of Radiation on a Mach–Zehnder Interferometer Silicon Modulator for HL-LHC Data Transmission Applications

Sarah Seif El Nasr-Storey, Charles Baudot, S. Détraz, Jean Marc Fédéli, Delphine Marris‐Morini, Lauri Olanterä, Giuseppe Pezzullo, Christophe Sigaud, Csaba Soós, J. Troska,

IEEE Transactions on Nuclear Science · 2015 · 44 citations · 10 references

DOIFull text

Open access

Concepts

Abstract

High-speed Mach-Zehnder interferometer silicon modulators were irradiated with neutrons and X-rays in two separate radiation tests. The devices were exposed to a total fluence of 1.2 ×10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">15</sup> neutrons/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and a total ionizing dose of 1.3 MGy; levels comparable to the worst radiation levels for a tracking detector after 10 years of operation at the High-Luminosity LHC. Our measurements indicate that the devices' performance does not significantly degrade after exposure to nonionizing radiation and begins to be affected by ionizing radiation after a dose of a few hundred kGy; the phase-shift for an applied reverse bias of 1 V is 10% of its preirradiated value after 600 kGy of received ionizing dose.