Journal of Physics D Applied Physics · 1976 · 15 citations · 4 references
Natural SciencesElectrical EngineeringAtmospheric ElectricityElectroanalytical MethodsElectrochemistryElectrical Properties Of RocksInduced PolarizationBreakdown CharacteristicsBreakdown StrengthBreakdown VoltageDissolved OxygenElectrical BreakdownElectrical Breakdown StrengthPolaritiesTransformer Insulation
The direct breakdown voltage of degassed transformer oil has been measured as a function of gap length using point-sphere electrodes, for both polarities of the point. Although changing the material of the sphere electrode altered the magnitude of the breakdown voltage for both point polarities, the critical gap length at which the breakdown voltage was the same for both polarities remained unchanged. This critical gap length was markedly reduced by the presence of dissolved oxygen.
4