Veterinary MedicineBiomedical EngineeringRadiologyDiagnostic ImagingDiagnostic RadiologyDigital Imaging3D ImagingComputed TomographyComputed Tomography PhysicsImage ReconstructionRadiation Imaging DetectorsRadiographic ImagingCone-beam Computed Tomography ReconstructionDetector Spatial ResolutionFlat-panel Detector SystemsFlat-panel DetectorsPoint Spread FunctionPoint Spread Function EstimationPoint Spread Function ModelingResolution Modeling
This work is intended to investigate the spatial resolution properties in cone beam CT by estimating the point spread functions (PSFs) in the reconstructed 3D images through simulation. The point objects were modeled as 3D delta functions. Their projections onto the detector plane were analytically derived and blurred with 2D PSFs estimated and used to represent the detector and focal spot blurring effects. The 2D PSF for detector blurring was computed from the line spread function measured for a typical a-Si/CsI flat panel detector used for general radiography. The focal spot blurring effect was simulated for an x-ray source with a nominal focal spot size of 0.6 mm and 1.33 x magnification at the rotating center. Projection images were computed and sampled with an interval significantly smaller than the detector pixel size to avoid aliasing. Images were reconstructed using the Feldkamp algorithm with the five different filter functions. Reconstructed PSFs were plotted and analyzed to investigate the effects of detector blurring alone, focal spot blurring alone, or a combination of the two on the PSFs and their variations with the radial distance and z-level. Effects of binning and reconstruction filters were also studied. Our results show that the PSFs due to detector blurring are largely symmetric and vary little with the locations of the point objects. With focal spot blurring only or added to detector blurring, the PSFs along the rotation axis were largely symmetric but became increasingly asymmetric as the point objects were moved away from the rotation axis. The PSFs were found to become wider in the axial (anode to cathode) direction as the objects were moved toward the cathode side. The 3D PSFs may be approximated by an ellipsoid with three different axial lengths. They were found to point upright along the rotating axis but tilt toward the rotating axis as the point object was moved away from the axis.
20
L.A. Feldkamp, L. C. Davis, J. W. Kress · Journal of the Optical Society of America A · 1984 · 6.2K citations
Dedicated Breast CT: Radiation Dose and Image Quality Evaluation
John M. Boone, Thomas R. Nelson, Karen K. Lindfors et al. · Radiology · 2001 · 464 citations
Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation
Yong Yang, Eduard Schreibmann, Tianfang Li et al. · Physics in Medicine and Biology · 2007 · 293 citations
Cone‐beam volume CT breast imaging: Feasibility study
Biao Chen, Ruola Ning · Medical Physics · 2002 · 276 citations