Analytical Chemistry · 2011 · 157 citations · 21 references
Natural SciencesBiochemistryAnalytical ChemistryLipid BiochemistryMass Spectrometric AnalysisChromatographyInstrumental AnalysisLipid AnalysisLipidomicsLiquid ChromatographyMass SpectrometryBlood LipidsLipid Composition AnalysisLipid ProfilingLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisLiquid Chromatography-mass Spectrometry Method DevelopmentMass Spectrometry-based LipidomicsTriglyceride Analysis In Body Fluids
There is a growing need both clinically and experimentally to improve the characterization of blood lipids. A liquid chromatography-mass spectrometry (LC-MS) method, developed for the qualitative and semiquantitative detection of lipids in biological samples and previously validated in mitochondrial samples, was now evaluated for the profiling of serum lipids. Data were acquired using high-resolution, full scan MS and high-energy, collisional dissociation (HCD), all ion fragmentation. The method was designed for efficient separation and detection in both positive and negative ionization mode and evaluated using standards spanning seven lipid classes. Platform performance, related to the identification and characterization of serum triglycerides (TGs), was assessed using extracted ion chromatograms with mass tolerance windows of 5 ppm or less from full scan exact mass measurements determined using SIEVE nondifferential LC-MS analysis software. The platform showed retention time coefficients of variation (CV) of <0.3%, mass accuracy values of <2 ppm error, and peak area CV of <13%, with the majority of that error coming from sample preparation and extraction rather than the LC-MS analysis, and linearity was shown to be over 4 orders of magnitude (r(2) = 0.999) for the standard TG (15:0)(3) spiked into serum. Instrument mass accuracy and precision were critical to the identification of unknown TG species, in part because these parameters enabled us to reduce false positives. In addition to detection and relative quantitation of TGs in serum, TG structures were characterized through the use of alternating HCD scans at different energies to produce diagnostic fragmentations on all ions in the analysis. The lipidomics method was applied to serum samples from 192 rats maintained on diets differing in macronutrient composition. The analysis identified 86 TG species with 81 unique masses that varied over 3.5 orders of magnitude and showed diet-dependency, consistent with TGs linking diet and disease risk.
21
Colin A. Smith, Grace O Maille, Elizabeth J. Want et al. · Therapeutic Drug Monitoring · 2005 · 2.2K citations
HMDB: a knowledgebase for the human metabolome
David S. Wishart, Craig Knox, An Chi Guo et al. · Nucleic Acids Research · 2008 · 1.9K citations · Full text
Lipidomics reveals a remarkable diversity of lipids in human plasma
Oswald Quehenberger, Aaron M. Armando, Alex Brown et al. · Journal of Lipid Research · 2010 · 1.3K citations · Full text