Clinical Chemistry and Laboratory Medicine (CCLM) · 2003 · 22 citations · 13 references
MedicineNeurosurgerySurgeryCerebrovascular NeurosurgeryCerebrovascular SurgeryVascular SurgeryBlood-brain Barrier BiologyBlood-brain Barrier DysfunctionCarotid EndarterectomyCerebral Perfusion MonitoringCerebrovascular DiseaseCerebrovascular PhysiologyBlood-brain Barrier Disruption BiomarkersBlood-brain Barrier PathologyBlood-brain Barrier PermeabilityHypoperfusion DetectionIntraoperative Cerebral MonitoringNeurological DysfunctionPeripheral Venous SamplingPostoperative Neurological Deficits
During carotid endarterectomy (CEA) the internal carotid artery is cross-clamped for a period of several minutes. This maneuver may cause cerebral hypoperfusion and/or impairment of the blood-brain barrier (BBB) even in cases where clinical signs are absent. The aim of the present study was to examine whether such alterations could be detected by monitoring the cerebral marker S-100B protein concentrations during and after CEA in the serum. Twenty-five consecutive patients (17 M/8 F, mean age: 64.2 years, range 47-79 years) undergoing elective CEA at our department were studied. All of these patients were without perioperative neurological deficit. Intraoperative samples were collected from internal jugular and peripheral venous blood: 1) before carotid cross-clamping; 2) immediately before declamping; 3) after clamp release. Postoperative samples were taken from peripheral blood at 6 and 24 h, respectively. S-100B was assayed in sera using an immunoluminometric technique. During carotid cross-clamping, S-100B protein concentrations in the ipsilateral jugular serum significantly (p < 0.02) increased to pre-clamp values. After declamping, however, S-100B returned to the baseline level. No differences were seen between the responses of hypertensive and normotensive patients. There was no correlation between carotid occlusion time and S-100B protein concentrations. In the peripheral venous serum no significant changes in S-100B concentrations were detected during or after CEA. We presume that the elevation of S-100B protein concentration during CEA in patients with no neurological deficits indicates the transient opening of the BBB elicited by carotid cross-clamping.
13
Release of Glial Tissue–Specific Proteins After Acute Stroke
Manfred Herrmann, Pieter E. Vos, Michael T. Wunderlich et al. · Stroke · 2000 · 399 citations
Serum S-100β as a possible marker of blood–brain barrier disruption
Miranda Kapural, Lj Krizanac-Bengez, Gene H. Barnett et al. · Brain Research · 2002 · 283 citations
S-100 Protein: Serum Marker of Focal Brain Damage After Ischemic Territorial MCA Infarction
Thomas Büttner, Stephan Weyers, Thomas Postert et al. · Stroke · 1997 · 260 citations