Particle size distribution in slaughterhouse wastewater before and after coagulation‐flocculation

M.I. Aguilar, J. Sáez, Mercedes Lloréns Pascual del Riquelme, Antonio Soler, J.F. Ortuño

Environmental Progress · 2003 · 26 citations · 11 references

Concepts

Abstract

Abstract Solid particles were removed from a slaughterhouse liquid effluent by physicochemical treatment (coagulation‐flocculation process) using aluminium sulfate as the coagulant, and activated silica, powdered activated carbon, precipitated calcium carbonate, polyacrylic acid, or anionic polyacrylamide as coagulant aids to improve the settling time. Once the optimal conditions of the coagulation‐flocculation process had been established (speed and time of stirring during flocculation, pH, coagulant and coagulant aid doses), the particle number and size distribution were measured before and after the addition of aluminium sulfate as the coagulant and the different coagulant aids, to determine the efficiency of the coagulation‐flocculation process. When aluminium sulfate was used without the coagulant aids, overall efficiency of particle removal was 87%. Use of powdered activated carbon, polyacrylic acid, or anionic polyacrylamide improved removal to values between 92 and 98%.

References

11