BMJ · 1973 · 152 citations · 16 references
Plasma Specific GravityElectrolyte DisorderInduced ChangesPlasma CalciumCellular PhysiologyBioanalysisElectrolyte DisturbanceClinical ChemistryLaboratory MedicineBiophysicsMineral MetabolismHealth SciencesMechanobiologySpecific Gravity CorrectionCalcium Specific ElectrodePharmacologyPhysiologyElectrophysiologyMedicine
The relationship of plasma calcium levels to changes in plasma specific gravity, total protein, and albumin induced by venous stasis was investigated. Factors were derived for adjusting calcium results to offset the effects of variation in protein concentration and thus to make them of increased discriminatory value to the clinician. The validity of an existing specific gravity correction has been substantiated, but a more exact adjustment of 0.23 mg/100 ml of calcium for every 0.001 change in specific gravity is proposed. We recommend for automated laboratories that the factor based on albumin be used: 0.09 mg/100 ml of calcium should be subtracted from the total calcium value for every increase of 0.1 g in albumin above 4.6 g/100 ml, and a corresponding addition should be made for values of albumin below 4.6 g/100 ml.Using a calcium specific electrode, it has been shown that the ionized calcium concentration does not alter with prolonged venous stasis.
16
Practical Clinical Biochemistry
Journal of the American Medical Association · 1955 · 1.5K citations
Interpretation of Serum Calcium in Patients with Abnormal Serum Proteins
R. B. Payne, A J Little, Richard B. Williams et al. · BMJ · 1973 · 915 citations · Full text
Practical Clinical Biochemistry
Postgraduate Medical Journal · 1959 · 286 citations