Journal of the American Society for Mass Spectrometry · 2000 · 199 citations · 30 references
Natural SciencesBiochemistryChemistryAnalytical ChemistryMass Spectrometric AnalysisSpectroscopyElectrostatic Interactions In BiomoleculesElectrostatics In BiomoleculesIonization TechniquesMass SpectrometrySolvation EffectsSpectroscopy Of BiomoleculesAnalyte SolvationCharge State DistributionsCharge-state DistributionCharge-state FormationElectrospray IonizationProton Transfer ReactionsQuadrupole Mass AnalyzersQuadrupole Mass Spectrometry
The effects of solvent composition on both the maximum charge states and charge state distributions of analyte ions formed by electrospray ionization were investigated using a quadrupole mass spectrometer. The charge state distributions of cytochrome c and myoglobin, formed from 47%/50%/3% water/solvent/acetic acid solutions, shift to lower charge (higher m/z) when the 50% solvent fraction is changed from water to methanol, to acetonitrile, to isopropanol. This is also the order of increasing gas-phase basicities of these solvents, although other physical properties of these solvents may also play a role. The effect is relatively small for these solvents, possibly due to their limited concentration inside the electrospray interface. In contrast, the addition of even small amounts of diethylamine (<0.4%) results in dramatic shifts to lower charge, presumably due to preferential proton transfer from the higher charge state ions to diethylamine. These results clearly show that the maximum charge states and charge state distributions of ions formed by electrospray ionization are influenced by solvents that are more volatile than water. Addition of even small amounts of two solvents that are less volatile than water, ethylene glycol and 2-methoxyethanol, also results in preferential deprotonation of higher charge state ions of small peptides, but these solvents actually produce an enhancement in the higher charge state ions for both cytochrome c and myoglobin. For instruments that have capabilities that improve with lower m/z, this effect could be taken advantage of to improve the performance of an analysis.
30
CRC Handbook of Chemistry and Physics
Devendra Leena P · Journal of Molecular Structure · 1992 · 9.4K citations
Natural Sciences, Chemistry, Physics +12
Analytical Properties of the Nanoelectrospray Ion Source
Matthias Wilm, Matthias Mann · Analytical Chemistry · 1996 · 1.9K citations
Malcolm Dole, L. L. Mack, R. L. Hines et al. · The Journal of Chemical Physics · 1968 · 1.6K citations
Natural Sciences, Chemistry, Physics +15
On the evaporation of small ions from charged droplets
J. V. Iribarne, B. A. Thomson · The Journal of Chemical Physics · 1976 · 1.2K citations
Natural Sciences, Chemistry, Physics +15