PLoS ONE · 2014 · 93 citations · 29 references
EngineeringBioengineeringBiomedical EngineeringBiomechanicsMechanobiologyStem Cell BiologyBiofluid MechanicsCell CultureCell Culture BioreactorsCell Culture TechnologyCellular BiomechanicsCellular MechanicsFluid Shear StressInduced Pluripotent Stem CellsParticle Image VelocimetryReynolds NumberShear StressShear Stress DistributionStress DistributionSuspension Culture
We present detailed quantitative measurement analyses for flow in a spinner flask with spinning rates between 20 to 45 RPM, utilizing the optical velocimetry measurement technique of Particle Image Velocimetry (PIV). A partial section of the impeller was immersed in the working fluid to reduce the shear forces induced on the cells cultured on microcarriers. Higher rotational speeds improved the mixing effect in the medium at the expense of a higher shear environment. It was found that the mouse induced pluripotent stem (iPS) cells achieved the optimum number of cells over 7 days in 25 RPM suspension culture. This condition translates to 0.0984 Pa of maximum shear stress caused by the interaction of the fluid flow with the bottom surface. However, inverse cell growth was obtained at 28 RPM culture condition. Such a narrow margin demonstrated that mouse iPS cells cultured on microcarriers are very sensitive to mechanical forces. This study provides insight to biomechanical parameters, specifically the shear stress distribution, for a commercially available spinner flask over a wide range of Reynolds number.
29
Scalable Production of Embryonic Stem Cell-Derived Cardiomyocytes
Peter W. Zandstra, Céline L. Bauwens, Tong Yin et al. · Tissue Engineering · 2003 · 267 citations
Fluid mechanics of a spinner‐flask bioreactor
Philippe Sucosky, Diego Osorio, Jason Brown et al. · Biotechnology and Bioengineering · 2003 · 212 citations