Direct comparison of optical lattice clocks with an intercontinental baseline of 9000  km

Hidekazu Hachisu, Miho Fujieda, S. Nagano, Tadahiro Gotoh, Asahiko Nogami, T. Ido, St. Falke, Nils Huntemann, Christian Grebing, B. Lipphardt,

Optics Letters · 2014 · 50 citations · 20 references

DOIFull text

Open access

Concepts

Abstract

We have demonstrated a direct frequency comparison between two ⁸⁷Sr lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique, based on the carrier-phase, was employed for a direct comparison, with a baseline of 9000 km between Japan and Germany. A frequency comparison was achieved for 83,640 s, resulting in a fractional difference of (1.1±1.6)×10⁻¹⁵, where the statistical part is the largest contributor to the uncertainty. This measurement directly confirms the agreement of the two optical frequency standards on an intercontinental scale.