WHEAT MOISTURE DETERMINATION BY 1- TO 110-MHZ SWEPT-FREQUENCY ADMITTANCE MEASUREMENTS

Kurt C. Lawrence, William R. Windham, S. O. Nelson

Transactions of the ASAE · 1998 · 31 citations · 0 references

Concepts

Abstract

A technique is presented for rapidly determining the moisture content of hard red winter wheat, Triticumaestivum L., independent of grain bulk density. Complex admittance measurements from 1 to 110 MHz on bulk wheatsamples were collected for predicting moisture contents ranging from about 9% to 20%, wet basis, in samples withdensities ranging from 0.620 to 0.790 g/cm3. The data were transformed to density-independent function (DIF) values,and multivariate analysis was used to eliminate spectral and statistical outliers. Principal component analysis was alsoused to determine the optimum frequencies for predicting moisture content with the DIF values. Partial least-squaresregression was then used to develop a calibration based on measurements at three frequencies of about 2, 25, and80 MHz. Calibration was performed with 47 wheat samples representing six cultivars harvested in 1991 and 1992 with astandard error of cross validation of 0.34% moisture content, and validation was tested on 146 different samples from thesame cultivars. Predicted moisture contents compared well with values determined by air oven drying with a standarderror of performance of 0.39% moisture content and a bias of +0.03%.