PLoS ONE · 2014 · 125 citations · 19 references
Life SciencesInfectious DiseasesMicrobiologyBacteriologyDiagnostic MicrobiologyMedical MicrobiologyAntimicrobial Susceptibility TestingBloodstream Infection DiagnosticsBloodstream InfectionsDiagnostic BacteriologyMicrobiological QualityPathogen DetectionAntimicrobial Susceptibility InterpretationBlood Culture BottlesBloodstream Infection DiagnosisMaldi-tof Mass SpectrometryMedical Microbial DiagnosisMicrobial Culture IdentificationMicrobial Susceptibility TestingRapid Blood Culture Identification
Rapid identification and antimicrobial susceptibility testing of microorganisms causing bloodstream infections or sepsis have the potential to improve patient care. This proof-of-principle study evaluates the Lysis-Filtration Method for identification as well as antimicrobial susceptibility testing of bacteria directly from positive blood culture bottles in a clinical setting. A total of 100 non-duplicated positive blood cultures were tested and 1012 microorganism-antimicrobial combinations were assessed. An aliquot of non-charcoal blood culture broth was incubated with lysis buffer briefly before being filtered and washed. Microorganisms recovered from the filter membrane were first identified by using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight VITEK® Mass Spectrometry (VITEK MS). After quick identification from VITEK MS, filtered microorganisms were inoculated to VITEK®2 system for full panel antimicrobial susceptibility testing analysis. Of 100 bottles tested, the VITEK MS resulted in 94.0% correct organism identification to the species level. Compared to the conventional antimicrobial susceptibility testing methods, direct antimicrobial susceptibility testing from VITEK®2 resulted in 93.5% (946/1012) category agreement of antimicrobials tested, with 3.6% (36/1012) minor error, 1.7% (7/1012) major error, and 1.3% (13/1012) very major error of antimicrobials. The average time to identification and antimicrobial susceptibility testing was 11.4 hours by using the Lysis-Filtration method for both VITEK MS and VITEK®2 compared to 56.3 hours by using conventional methods (p<0.00001). Thus, the same-day results of microorganism identification and antimicrobial susceptibility testing directly from positive blood culture can be achieved and can be used for appropriate antibiotic therapy and antibiotic stewardship.
19
Angela Huang, Duane W. Newton, Anjly Kunapuli et al. · Clinical Infectious Diseases · 2013 · 509 citations · Full text
Lindsay G. Stevenson, Steven K. Drake, Patrick R. Murray · Journal of Clinical Microbiology · 2009 · 425 citations · Full text
Martin Christner, Holger Rohde, Manuel Wolters et al. · Journal of Clinical Microbiology · 2010 · 304 citations · Full text