Physical Review · 1934 · 32 citations · 7 references
Natural SciencesPhysicsMaterials CharacterizationRadiation MeasurementSpectroscopyX-ray Data AnalysisX-ray SpectroscopySpectrometer CalibrationX-ray Spectra
The full widths at half-maximum of the $L{\ensuremath{\alpha}}_{1}$, $L{\ensuremath{\beta}}_{1}$, $L{\ensuremath{\beta}}_{2}$ and $L{\ensuremath{\gamma}}_{1}$ lines of Bi, Pb, Tl, Au, Pt, Ir and W have been measured with Allison's double spectrometer in the (1, +1) position equipped with previously calibrated calcite crystals of high perfection. The results in X.U. are given in the table. The widths are uncorrected for the finite resolving power of the crystals or for the geometrical divergence of the x-ray beam. Approximate small corrections have been made for interfering lines. Relative wave-lengths of neighboring lines are given. Empirical relations between the energy widths of the lines investigated and the atomic number and the electron transitions involved are suggested. The effects of alloys of the elements on the widths observed are discussed.
7
The Reflecting and Resolving Power of Calcite for X-rays
Samuel K. Allison · Physical Review · 1932 · 52 citations
Archer Hoyt · Physical Review · 1932 · 42 citations
Samuel K. Allison, John H. Williams · Physical Review · 1930 · 39 citations
Lyman G. Parratt · Physical Review · 1933 · 29 citations