Publication | Closed Access
High performance, room temperature, broadband II-VI quantum cascade detector
39
Citations
22
References
2015
Year
Optical MaterialsEngineeringHigh PerformanceQuantum SensingPhotoelectric SensorQuantum ComputingExperimental DemonstrationOptical PropertiesPhotophysical PropertyQuantum SciencePhotonicsPhysicsQuantum DeviceThermal PhysicsPhotoelectric MeasurementRadiometryOptical SensorsRoom TemperatureBlackbody Responsivity MeasurementsQuantum TechnologyNatural SciencesSpectroscopyApplied PhysicsOptoelectronics
We report on the experimental demonstration of a room temperature, II-VI, ZnCdSe/ZnCdMgSe, broadband Quantum Cascade detector. The detector consists of 30 periods of 2 interleaved active-absorption regions centered at wavelengths 4.8 μm and 5.8 μm, respectively. A broad and smooth photocurrent spectrum between 3.3 μm and 6 μm spanning a width of 1030 cm–1 measured at 10% above baseline was obtained up to 280 K, corresponding to a ΔE/E of 47%. Calibrated blackbody responsivity measurements show a measured peak responsivity of 40 mA/W at 80 K, corresponding to a detectivity of about 3.1×1010 cmHz/W. Bias dependent photocurrent measurements revealed no significant change in the spectral shape, suggesting an impedance matched structure between the different active regions.