TURKISH JOURNAL OF CHEMISTRY · 2012 · 12 citations · 0 references
MedicineChemistryNephrologySpectroscopic AnalysisSpectroscopyUrolithiasisInfrared SpectroscopyUric Acid StonesUrinary Stone CompositionFourier TransformInfrared Absorption SpectroscopyInfrared Spectroscopic AnalysisRapid Screening TestsRenal Stone DetectionStone Spectroscopy
The purpose of the present study was to investigate the composition of kidney stones removed from human patients. Seventeen samples were collected after surgery (5 females and 12 males; age range 2 to 60 years). The samples were analyzed for composition by transmission Fourier transform infrared (FT-IR) spectroscopy. The 17 analyzed samples of kidney stones comprised 29.4% calcium oxalate, 29.4% uric acid, 29.4% calcium oxalate (CaOx)-uric acid, 5.9% phosphate, and 5.9% calcium oxalate-phosphate stones. The results of the study indicated that transmission FT-IR spectroscopy could be used as an environmentally friendly technique for rapid screening of kidney stones.