Impact of verification media and resuscitation on accuracy of the membrane filter total coliform enumeration technique

Thomas M. Evans, Ramon J. Seidler, Mark W. LeChevallier

Applied and Environmental Microbiology · 1981 · 28 citations · 14 references

DOIFull text

Open access

Concepts

Abstract

Verification of membrane filter total coliform colonies was compared in lauryl tryptose broth, and m-LAC broth primary media and brilliant green-lactose-bile broth and EC broth secondary media. Verification in m-LAC broth yielded the greatest number of aerogenic isolates for both untreated surface water and drinking water samples. Verification in brilliant green-lactose-bile broth increased the number of false-negative reactions. At least 90% of the isolates aerogenic in primary verification media and anaerogenic in brilliant green-lactose-bile broth were representative of the coliform genera. The addition of a resuscitation step in the membrane filter technique did not yield greater numbers of verified coliforms per sample. Verification of both typical and atypical colonies in m-LAC broth resulted in a 10-fold increase in coliform numbers from untreated surface water. With drinking water, verification of both colony types resulted in an increase from less than 1 coliform per 100 ml to greater than 1/100 ml. A single-step verification in m-LAC broth is proposed as a more rapid and sensitive coliform verification procedure than the standard technique.

References

14