Determination of gold and silver in dross using EDXRF technique

Madhusudan Ghosh, K. K. Swain, Trupti A. Chavan, D. N. Wagh, Rakesh Kumar Verma

X-Ray Spectrometry · 2014 · 13 citations · 8 references

DOIFull text

Open access

Concepts

Abstract

Gold and silver in dross were determined by energy‐dispersive X‐ray fluorescence technique. Sample was prepared by pressed pellet method using microcrystalline cellulose powder as binder, and a method of standard additions was used for quantification. L β X‐ray of gold (11.4 keV) and K β X‐ray of silver (24.9 keV) were used for analysis. The measured concentrations of gold and silver were 132 ± 8 and 1181 ± 84 mg kg −1 , respectively. The results were validated by instrumental neutron activation analysis technique. The t ‐test indicated that there was no significant difference between results obtained by the two techniques. Energy‐dispersive X‐ray fluorescence is a simple, precise and accurate technique for the determination of gold and silver in dross. Copyright © 2014 John Wiley & Sons, Ltd.

References

8