2007 · 187 citations · 0 references
Natural SciencesChemistryAnalytical ChemistryMetrologySpectroscopyOptical MetrologyOptical SpectroscopyPhotometric SystemsSpectroscopic Method ValidationUltraviolet PolarimetryPhotometric MeasurementPolarimetric MetrologyPolarimetry
Abstract. The proliferation of near-infrared (1–5 µm) photometric systemsover the last 30 years has made the comparison of photometric results difficult.In an effort to standardize infrared filters in use, the Mauna Kea Observatoriesnear-infrared filter set has been promoted among instrument groups throughcombined filter production runs. The characteristics of this filter set are sum-marized, and some aspects of the filter wavelength definitions, the flux densityfor zero magnitude, atmospheric extinction coefficients, and color correction toabove the atmosphere are discussed. 1. IntroductionThe foundations of modern infrared photometry at near-infrared wavelengths(1–5 µm) were built upon the pioneering work of Johnson and his collaborators(Johnson 1966; Johnson et al. 1966; Johnson, MacArthur, & Mitchell 1968).The near-infrared filters used in these early works were very broad, and theatmospheric absorption bands defined the effective widths of the filters. Thefilter profiles used by Johnson (1965) are shown in Fig. 1, which demonstratesthat the deep atmospheric absorption bands (mostly due to water vapor) playa significant role in determining the effective transmission of the atmosphere +telescope + filter observational system.The problem with allowing the atmosphere to define the passband is thatthe atmosphere varies substantially from place to place and, at any given loca-tion, from night to night (even from hour to hour). Hence, the reproducibility ofphotometricobservationsandconversionstootherphotometricsystems becomesdifficult or impossible to achieve. To prevent these problems, the photometricbands should ideally be defined by only the filter transmission profiles (if possi-ble). Ideally, the filter bandpasses should avoid deep telluric absorption featuresand any part of the telluric spectrum that has a large first derivative and/or ishighly variable. In principle, filter properties can be controlled by the manufac-turer, and so the specifications and characteristics of the filters are usually theonly aspect of the observational system that can remain constant from instru-ment to instrument and site to site. If such a set of filters were easily replicableand distributed to a large number of observatories, the comparison of photomet-409