The Structural engineer · 1971 · 13 citations · 0 references
EngineeringCivil EngineeringMaterials EngineeringConstruction TechnologyStructural EngineeringStructural MaterialsBending Of BeamsBolted ConnectionsComposite MaterialsComposite StructuresConcrete MaterialsReinforced Concrete StructuresComposite ConnectionsConnectorsShear BehaviorShear Connection DesignShear Connections
EXPERIMENTS WERE CONDUCTED ON THE USE OF THE HIGH STRENGTH FRICTION-GRIP BOLT TO PROVIDE THE SHEAR CONNECTION BETWEEN THE CONCRETE SLAB AND STEEL BEAM IN COMPOSITE CONSTRUCTION. STATIC PUSH-OUT TESTS WERE MADE TO DETERMINE THE STRENGTH OF SUCH CONNECTORS. TESTS WERE ALSO MADE ON BEAMS, SOME WITH PRECAST AND OTHERS WITH CAST-IN-SITU SLABS USING THEM. THE RESULTS SHOW THAT THE HIGH-STRENGTH FRICTION-GRIP BOLT CAN BE USED AS AN EFFICIENT CONNECTOR IN COMPOSITE CONSTRUCTION. /RRL(A)/