Forest Products Journal · 1997 · 31 citations · 0 references
Life SciencesAnimal SciencesZoologyDiagnostic ParasitologyForest EntomologySensory EvaluationPest DetectionTermite BiologyTermite ControlControlsInsect Infestation AssessmentLaboratory Test EvaluationLaboratory Test ValidationOdor DetectionSearchesSensory Evaluation Of OdorsSensory Odor Evaluation
Laboratory blind trials were conducted to evaluate the ability of beagles and an electronic odor device to detect termites in wood. In the first test, pine blocks artificially infested with either 0, 5, 50, or 200 workers of the western subterranean termite, Reticulitermes hesperus Banks, were randomly presented to five beagles and one electronic odor device. Blocks were presented one at a time to beagles and the electronic odor device. The beagles correctly identified 81 percent of the blocks while the electronic odor device correctly identified 48 percent. A second laboratory test comparing five additional electronic odor devices from the same manufacturer resulted in a slightly higher correctly identified value, 62 percent. Beagles performed best for blocks containing 50 or more termites. However, the percentage of misidentified controls (false positives) for beagles was high, 28 percent. The electronic odor device did not demonstrate statistically significant detection ability. Although beagles were almost perfect (49 of 50 blocks) in detecting termites in blocks with 50 or more individuals, neither detection method was reliable with control samples or with samples with a low number of termites. The implications of these findings to the use of either of these termite detection methods are discussed.