European Journal of Cancer · 2025 · 11 citations · 23 references
MedicineOncologyPathologyBiomedical ImagingComputer VisionTumor MicroenvironmentCell-type DeconvolutionComputational OncologyImmunohistochemistryTumor Immune MicroenvironmentTumor-associated MacrophagesArtificial Intelligence For DetectionCancer-associated MacrophagesImage-based Tumor DetectionPathology Image AnalysisSquamous Cell Carcinoma HistologySquamous Cell Carcinoma PathologyTumor Microenvironment ImagingTumor Microenvironment Mapping
BACKGROUND: Virtual staining is an artificial intelligence-based approach that transforms pathology images between stain types, such as hematoxylin and eosin (H&E) to immunohistochemistry (IHC), providing a tissue-preserving and efficient alternative to traditional IHC staining. However, existing methods for translating H&E to virtual IHC often fail to generate images of sufficient quality for accurately delineating cell nuclei and IHC+ regions. To address these limitations, we introduce VISTA, an artificial intelligence-based virtual staining platform designed to translate H&E into virtual IHC. METHODS: We applied VISTA to identify M2-subtype tumor-associated macrophages (M2-TAMs) in H&E images from 968 patients with HPV+ oropharyngeal squamous cell carcinoma across six institutional cohorts. M2-TAMs are a critical component of the tumor microenvironment, and their increased presence has been linked to poor survival. Co-registered H&E and CD163 + IHC tissue microarrays were used to train (D1, N = 102) and test (D2, N = 50) the VISTA platform. M2-TAM density, defined as the ratio of M2-TAMs to total nuclei, was derived from VISTA-generated CD163 + IHC images and evaluated for prognostic significance in additional training (D3, N = 360) and testing (D4, N = 456) cohorts using biopsy or resection H&E whole slide images. RESULTS: High M2-TAM density was associated with worse overall survival in D4 (p = 0.0152, Hazard Ratio=1.63 [1.1-2.42]). VISTA outperformed existing methods, generating higher-quality virtual CD163 + IHC images in D2, with a Structural Similarity Index of 0.72, a Peak Signal-to-Noise Ratio of 21.5, and a Fréchet Inception Distance of 41.4. Additionally, VISTA demonstrated superior performance in segmenting M2-TAMs in D2 (Dice=0.74). CONCLUSION: These findings establish VISTA as a computational platform for generating virtual IHC and facilitating the discovery of novel biomarkers from H&E images.
23
Unpaired Image-to-Image Translation Using Cycle-Consistent Adversarial Networks
Jun-Yan Zhu, Taesung Park, Phillip Isola et al. · 2017 · 21.9K citations · Full text
Hematoxylin and Eosin Staining of Tissue and Cell Sections
Andrew H. Fischer, Kenneth A. Jacobson, Jack Rose et al. · Cold Spring Harbor Protocols · 2008 · 2.1K citations
Maura L. Gillison, Andy Trotti, Jonathan Harris et al. · The Lancet · 2018 · 1.3K citations
Towards a general-purpose foundation model for computational pathology
Richard J. Chen, Tong Ding, Ming Y. Lu et al. · Nature Medicine · 2024 · 1.1K citations · Full text
A visual-language foundation model for computational pathology
Ming Y. Lu, Bowen Chen, Drew F. K. Williamson et al. · Nature Medicine · 2024 · 698 citations · Full text