PLoS ONE · 2024 · 11 citations · 21 references
EducationKinesiologyPhysical EducationExercise PhysiologyExercise TestingPhysical ActivityMuscle Strength AssessmentMuscle Strength TestingMuscular StrengthMuscular Strength TestingPhysical FitnessPhysical Performance AssessmentCriteria Of ValidityExercise Test ReliabilityMean Power OutputMuscle Power TestingPeak VelocitySquatTransducersVelocity
This study aimed to determine the validity and between-day reliability of the mean velocity (MV), peak velocity (PV), mean power (MP), and peak power (PP) provided by the Vitruve linear position transducer at different submaximal loads in the free-weight and Smith machine back squat using GymAware as a reference point. Fourteen male sports science students (free-weight back squat one-repetition maximum [1RM]: 132.5 ± 28.5 kg, Smith machine back squat 1RM: 163.9 ± 30.4 kg) performed six experimental sessions, twice per week with 72 hours of rest. The first two included the assessment of the 1RM of both exercises. In the four remaining, both linear position transducers were simultaneously used to record MV, PV, MP, PP of each repetition during an incremental load test (i.e., 20, 40, 60, 80, 90% 1RM) with three minutes of rest between sets. Vitruve displayed both fixed and proportional bias for certain relative loads across all variables. Vitruve did not meet the validity criteria for all (MV, PP) or at least two (MP, PV) relative loads (Coefficient of variation [CV] > 10%; Pearson correlation < 0.70; Effect size > 0.60). MV, PV, MP, and PP recorded by Vitruve displayed acceptable reliability (CV < 10%) with superior reliability observed during a Smith Machine compared to free-weight back squat, and for velocity compared to power variables. Considering GymAware as a reference point, Vitruve was not valid for measuring velocity and power outcomes. Acceptable validity was observed only for PV in the Smith machine back squat, while the other variables-regardless of relative loads and exercise modes-were mostly inaccurate. All variables demonstrated acceptable reliability, with greater reliability noted in the Smith machine compared to the free-weight back squat exercise mode.
21
Velocity-Based Training: From Theory to Application
Jonathon Weakley, Bryan Mann, Harry G. Banyard et al. · Strength and conditioning journal · 2020 · 434 citations
Sophia Nimphius · Strength and conditioning journal · 2012 · 424 citations
Alejandro Pérez‐Castilla, Antonio Piepoli, Gabriel Delgado‐García et al. · The Journal of Strength and Conditioning Research · 2019 · 274 citations · Full text