PLoS Computational Biology · 2024 · 13 citations · 39 references
MedicineCardiologySurgeryHemodynamic ManagementInterventional CardiologySurgical InstrumentationAnticoagulant TherapyAntithrombotic TherapyAtrial FibrillationMedical Device SafetyThromboembolic DiseaseThrombosisAnatomical Variability AssessmentDevice ThrombosisLeft Atrial Appendage AnatomyLeft Atrial Appendage MorphologyLeft Atrial Appendage Occlusion DevicesLeft Atrial Appendage ThrombosisLeft Atrial Appendage ThrombusLeft Atrial Function
Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation.
39
The lift on a small sphere in a slow shear flow
P. G. Saffman · Journal of Fluid Mechanics · 1965 · 3.3K citations
5-Year Outcomes After Left Atrial Appendage Closure
Vivek Y. Reddy, Shephal K. Doshi, Saibal Kar et al. · Journal of the American College of Cardiology · 2017 · 991 citations · Full text
A shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Warwick S. Nesbitt, Erik Westein, Francisco J. Tovar‐Lopez et al. · Nature Medicine · 2009 · 851 citations · Full text
Medicine, Cell Biology, Hematology +12