Journal of Clinical Microbiology · 2024 · 11 citations · 15 references
Veterinary MedicineInfectious DiseasesMicrobiologyBacteriologyDiagnostic MicrobiologyMedical MicrobiologyAntimicrobial Susceptibility TestingBacterial InfectionsBloodstream Infection DiagnosticsPathogen DetectionRapid Diagnostic TestsAntibiotic Susceptibility TestingAssay ReproducibilityComparative Assay EvaluationGram-negative Bloodstream InfectionInter-laboratory ComparisonMicrobial Susceptibility TestingMicrofluidic Diagnostic PlatformsRapid Phenotypic Susceptibility Testing
ABSTRACT Common phenotypic methods for antimicrobial susceptibility testing (AST) of bacteria are slow, labor intensive, and display considerable technical variability. The QuickMIC system provides rapid AST using a microfluidic linear gradient. Here, we evaluate the performance of QuickMIC at four different laboratories with regard to speed, precision, accuracy, and reproducibility in comparison to broth microdilution (BMD). Spiked ( n = 411) and clinical blood cultures ( n = 148) were tested with the QuickMIC Gram-negative panel and compared with BMD for the 12 on-panel antibiotics, and 10 defined strains were run at each site to measure reproducibility. Logistic and linear regression analysis was applied to explore factors affecting assay performance. The overall essential agreement and categorical agreement between QuickMIC and BMD were 95.6% and 96.0%, respectively. Very major error, major error, and minor error rates were 1.0%, 0.6%, and 2.4%, respectively. Inter-laboratory reproducibility between the sites was high at 98.9% using the acceptable standard of ±1 twofold dilution. The mean in-instrument analysis time overall was 3 h 13 min (SD: 29 min). Regression analysis indicated that QuickMIC is robust with regard to initial inoculum and delay time after blood culture positivity. We conclude that QuickMIC can be used to rapidly measure MIC directly from blood cultures in clinical settings with high reproducibility, precision, and accuracy. The microfluidics-generated linear gradient ensures high reproducibility between laboratories, thus allowing a high level of trust in MIC values from single testing, at the cost of reduced measurement range compared to BMD. IMPORTANCE Increasing antimicrobial resistance underscores the need for new diagnostic solutions to guide therapy, but traditional antimicrobial susceptibility testing (AST) is often inadequate in time-critical diseases such as sepsis. This work presents a novel and rapid AST system with a rapid turnaround of results, which may help reduce the time to guided therapy, possibly allowing early de-escalation of broad-spectrum empirical therapy as well as rapid adjustments to treatments when coverage is lacking.
15
Alessandro Cassini, Liselotte Diaz Högberg, Diamantis Plachouras et al. · The Lancet Infectious Diseases · 2018 · 3K citations · Full text
Veterinary Medicine, Health Sciences, Infectious Diseases +17
MIC-based dose adjustment: facts and fables
Johan W. Mouton, Anouk E. Muller, Rafael Cantón et al. · Journal of Antimicrobial Chemotherapy · 2017 · 327 citations · Full text
Emma Jonasson, Erika Matuschek, Gunnar Kahlmeter · Journal of Antimicrobial Chemotherapy · 2019 · 183 citations · Full text
Jasper Van Heuverswyn, John Karlsson Valik, Suzanne D. van der Werff et al. · Clinical Infectious Diseases · 2022 · 161 citations · Full text