Translational Vision Science & Technology · 2024 · 11 citations · 33 references
MedicineNeurologyOphthalmologyComputer VisionNeuro-ophthalmologyOcular ImagingComputer-aided DiagnosisImage FusionMultiple SclerosisNeuro-ophthalmic ImagingOptical Coherence TomographyScanning Laser OphthalmoscopyConvolutional Neural NetworksData LeakageHigh-resolution Fundus ImagingMachine Learning For Optical DiagnosisMultimodal Image ProcessingMultimodal Retinal ImagingMultiple Sclerosis ModelsRetinal Image Processing
Purpose: Several machine learning studies have used optical coherence tomography (OCT) for multiple sclerosis (MS) classification with promising outcomes. Infrared reflectance scanning laser ophthalmoscopy (IR-SLO) captures high-resolution fundus images, commonly combined with OCT for fixed B-scan positions. However, no machine learning research has utilized IR-SLO images for automated MS diagnosis. Methods: This study utilized a dataset comprised of IR-SLO images and OCT data from Isfahan, Iran, encompassing 32 MS and 70 healthy individuals. A number of convolutional neural networks (CNNs)-namely, VGG-16, VGG-19, ResNet-50, ResNet-101, and a custom architecture-were trained with both IR-SLO images and OCT thickness maps as two separate input datasets. The highest performing models for each modality were then integrated to create a bimodal model that receives the combination of OCT thickness maps and IR-SLO images. Subject-wise data splitting was employed to prevent data leakage among training, validation, and testing sets. Results: Overall, images of the 102 patients from the internal dataset were divided into test, validation, and training subsets. Subsequently, we employed a bootstrapping approach on the training data through iterative sampling with replacement. The performance of the proposed bimodal model was evaluated on the internal test dataset, demonstrating an accuracy of 92.40% ± 4.1% (95% confidence interval [CI], 83.61-98.08), sensitivity of 95.43% ± 5.75% (95% CI, 83.71-100.0), specificity of 92.82% ± 3.72% (95% CI, 81.15-96.77), area under the receiver operating characteristic (AUROC) curve of 96.99% ± 2.99% (95% CI, 86.11-99.78), and area under the precision-recall curve (AUPRC) of 97.27% ± 2.94% (95% CI, 86.83-99.83). Furthermore, to assess the model generalization ability, we examined its performance on an external test dataset following the same bootstrap methodology, achieving promising results, with accuracy of 85.43% ± 0.08% (95% CI, 71.43-100.0), sensitivity of 97.33% ± 0.06% (95% CI, 83.33-100.0), specificity of 84.6% ± 0.10% (95% CI, 71.43-100.0), AUROC curve of 99.67% ± 0.02% (95% CI, 95.63-100.0), and AUPRC of 99.65% ± 0.02% (95% CI, 94.90-100.0). Conclusions: Incorporating both modalities improves the performance of automated diagnosis of MS, showcasing the potential of utilizing IR-SLO as a complementary tool alongside OCT. Translational Relevance: Should the results of our proposed bimodal model be validated in future work with larger and more diverse datasets, diagnosis of MS based on both OCT and IR-SLO can be reliably integrated into routine clinical practice.
33
Deep Residual Learning for Image Recognition
Kaiming He, Xiangyu Zhang, Shaoqing Ren et al. · 2016 · 222.1K citations · Full text
ImageNet: A large-scale hierarchical image database
Jia Deng, Wei Dong, Richard Socher et al. · 2009 IEEE Conference on Computer Vision and Pattern Recognition · 2009 · 61.8K citations
Leo Breiman · Machine Learning · 1996 · 16.4K citations · Full text
Index for rating diagnostic tests
W. J. Youden · Cancer · 1950 · 11.5K citations · Full text
Education, Educational Assessment, Educational Measurement +11