Heart Rhythm · 2024 · 16 citations · 11 references
MedicineCardiologyInterventional CardiologyPatient SafetyPerioperative SafetyCardiac PacingMedical Device SafetyPacemaker CareComplication Rate AnalysisHis Bundle PacingIntracardiac PacingLeft Bundle Branch Area PacingPacemaker ComplicationsPacingPacing ThresholdsProduct Safety Surveillance
BACKGROUND: Conduction system pacing (CSP), including His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP), has been used as an alternative for pacemaker indicated patients requiring ventricular pacing. OBJECTIVE: The purpose of this study was to characterize the safety and performance of HBP and LBBAP among patients enrolled in the Medtronic product surveillance registry (PSR). METHODS: This observational analysis included patients who underwent pacemaker implantations for HBP or LBBAP with a Medtronic Model 3830 lead between January 2019 and December 2023 in the Medtronic PSR. The primary outcomes were lead-related complications and pacing capture threshold. Baseline characteristics, R-wave amplitude, impedance, and all-cause mortality were summarized. RESULTS: A total of 2342 patients were included across 77 centers (mean age 74 years; 38.9% female). Of the patients implanted with a 3830 lead for CSP, 64.1% (n = 1502) had LBBAP placement and 35.9% (n = 840) had HBP placement. The most commonly reported indications for CSP were sinus node dysfunction (67.0%) and atrioventricular block (57.2%). LBBAP had lower pacing thresholds, higher R-wave sensing, and higher impedance (all P <.001) through 30 months. At 36 months postimplant, the lead complication rate for LBBAP and HBP was 2.5% and 6.3%, ,respectively with no difference in all-cause mortality. CONCLUSION: In a multicenter cohort of LBBAP and HBP patients treated with the catheter-delivered 3830 lead, lead-related complication rates were low and electrical parameters were stable through 30 months.
11
Hadley Wickham, Mara Averick, Jennifer Bryan et al. · The Journal of Open Source Software · 2019 · 21.6K citations · Full text
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Michael Glikson, Jens Cosedis Nielsen, Mads Brix Kronborg et al. · European Heart Journal · 2021 · 1.9K citations · Full text
Erich L. Kiehl, Tarek Makki, Rahul Kumar et al. · Heart Rhythm · 2016 · 472 citations
Incidence and predictors of right ventricular pacing-induced cardiomyopathy
Shaan Khurshid, Andrew E. Epstein, Ralph J. Verdino et al. · Heart Rhythm · 2014 · 415 citations