Aggregate · 2024 · 46 citations · 43 references
EngineeringBioengineeringBiomedical EngineeringAnalytical ChemistryBiosensorsNanomaterialsFluorescence SpectroscopyNanomaterial-based BiosensorsNanoparticle-based ImmunotechnologyNanosensorsOptical BiosensingOptical BiosensorsAccuracyFluorescence Quantum YieldFluorescent ProbesLateral Flow AssaysLuminescent BiosensorsNanoparticle-based BiosensorsPortable Analytical InstrumentsQuantum Efficiency
Abstract Accurate and sensitive near‐infrared (NIR) luminescent lateral flow immunoassay (LFIA) has attracted considerable attention in the field of point‐of‐care testing (POCT). However, the detection accuracy and sensitivity are often compromised by the low fluorescence quantum efficiency (<10%) of the NIR fluorescent probe. Herein, ultrabright NIR AIEgen nanoparticles (PS@AIE 830 NPs) composed of polystyrene (PS) nanoparticles and NIR aggregation‐induced emission luminogen (AIEgen) with the maximum emission at 830 nm (AIE 830 ) is reported, and its potential to promote an accurate and sensitive detection of complex samples by LFIA is described. The relative quantum yield (QY) of the PS@AIE 830 NPs was 14.76%, which was superior to that of the polymer embedding method and indocyanine green (ICG)‐based NIR nanoparticles. The PS@AIE 830 NPs immunolabeled‐LFIA combined with laboratory‐built NIR‐LFIA portable quantitative instruments (detected light range > 800 nm) completely eliminated background interference and allowed highly accurate and sensitive detection without any pre‐treatment steps. The limits of detection (LODs) for aflatoxin B 1 (AFB 1 ) in soy sauce, alpha hemolysin (Hla) of Staphylococcus aureus biomarker in joint fluid, and C‐reactive protein (CRP) in human haemolysed samples were 0.01 ng mL −1 , 0.02 µg mL −1 , and 0.156 mg L −1 , respectively, commensurating with those of the corresponding gold standard assays and covering the detection range of interests. It is anticipated that the ultrabright NIR AIEgen nanoparticles will serve as a universally applicable signal probe for NIR‐LFIA diagnostics, promising to expand the range of applications for quantitative detection of complex samples.
43
Aggregation‐enhanced theranostics: AIE sparkles in biomedical field
Miaomiao Kang, Zhijun Zhang, Nan Song et al. · Aggregate · 2020 · 493 citations · Full text
Rational Design of Molecular Fluorophores for Biological Imaging in the NIR‐II Window
Qinglai Yang, Zhuoran Ma, Huasen Wang et al. · Advanced Materials · 2017 · 458 citations
Zhanjun Li, Yuanwei Zhang, Xiang Wu et al. · Journal of the American Chemical Society · 2015 · 433 citations · Full text
Tissue-Specific Near-Infrared Fluorescence Imaging
Eric A. Owens, Maged Henary, Georges El Fakhri et al. · Accounts of Chemical Research · 2016 · 403 citations
Engineering, Oncology, Radiology +11