MedicineNeurosurgerySurgeryBiomedical ImagingDiagnostic ImagingEndoscopic NeurosurgeryEndoscopic Skull Base SurgeryImage RegistrationIntraoperative NavigationSkull Base ReconstructionSkull Base SurgeryThree-dimensional ReconstructionAnterior Skull Base ReconstructionImage-guided Endoscopic Sinus SurgeryImage-guided Skull Base SurgeryImage-guided Surgical NavigationIntraoperative Image GuidanceIntraoperative RegistrationSlam-based ReconstructionSphenoid Sinus Surgery
Importance: Image guidance is an important adjunct for endoscopic sinus and skull base surgery. However, current systems require bulky external tracking equipment, and their use can interrupt efficient surgical workflow. Objective: To evaluate a trackerless surgical navigation system using 3-dimensional (3D) endoscopy and simultaneous localization and mapping (SLAM) algorithms in the anterior skull base. Design, Setting, and Participants: This interventional deceased donor cohort study and retrospective clinical case study was conducted at a tertiary academic medical center with human deceased donor specimens and a patient with anterior skull base pathology. Exposures: Participants underwent endoscopic endonasal transsphenoidal dissection and surface model reconstruction from stereoscopic video with registration to volumetric models segmented from computed tomography (CT) and magnetic resonance imaging. Main Outcomes and Measures: To assess the fidelity of surface model reconstruction and accuracy of surgical navigation and surface-CT model coregistration, 3 metrics were calculated: reconstruction error, registration error, and localization error. Results: In deceased donor models (n = 9), high-fidelity surface models of the posterior wall of the sphenoid sinus were reconstructed from stereoscopic video and coregistered to corresponding volumetric CT models. The mean (SD; range) reconstruction, registration, and localization errors were 0.60 (0.24; 0.36-0.93), 1.11 (0.49; 0.71-1.56) and 1.01 (0.17; 0.78-1.25) mm, respectively. In a clinical case study of a patient who underwent a 3D endoscopic endonasal transsphenoidal resection of a tubercular meningioma, a high-fidelity surface model of the posterior wall of the sphenoid was reconstructed from intraoperative stereoscopic video and coregistered to a volumetric preoperative fused CT magnetic resonance imaging model with a root-mean-square error of 1.38 mm. Conclusions and Relevance: The results of this study suggest that SLAM algorithm-based endoscopic endonasal surgery navigation is a novel, accurate, and trackerless approach to surgical navigation that uses 3D endoscopy and SLAM-based algorithms in lieu of conventional optical or electromagnetic tracking. While multiple challenges remain before clinical readiness, a SLAM algorithm-based endoscopic endonasal surgery navigation system has the potential to improve surgical efficiency, economy of motion, and safety.
30
3D Slicer as an image computing platform for the Quantitative Imaging Network
Andriy Fedorov, Reinhard Beichel, Jayashree Kalpathy–Cramer et al. · Magnetic Resonance Imaging · 2012 · 8.9K citations · Full text
Arts, Computer Science, Radiology +12
elastix: A Toolbox for Intensity-Based Medical Image Registration
Stefan Klein, Marius Staring, Keelin Murphy et al. · IEEE Transactions on Medical Imaging · 2009 · 4.4K citations
Complications in endoscopic sinus surgery for chronic rhinosinusitis
James A. Stankiewicz, Devyani Lal, Matthew P. Connor et al. · The Laryngoscope · 2011 · 251 citations
Medicine, Otolaryngology, Surgery +13
Bareum Choi, Kyungmin Jo, Songe Choi et al. · 2017 · 109 citations
Computing, Computer Science, Surgery +16