Microbiology Spectrum · 2024 · 13 citations · 23 references
Veterinary MedicineInfectious DiseasesMicrobiologyAntimicrobial ResistanceDiagnostic MicrobiologyMedical MicrobiologyAntibiotic ResistanceAntimicrobial Susceptibility TestingBacterial InfectionsBloodstream Infection DiagnosticsHealthcare-associated Infection PreventionPathogen DetectionAnalytical Detection LimitsAntibiotic Susceptibility TestingCommunity-acquired Bacterial InfectionsMethicillin ResistanceMolecular Point-of-care TestingPathogen Detection SensitivityPoint-of-care Microbiology TestingStaphylococcus Aureus Detection
ABSTRACT Staphylococcus aureus ( S. aureus ) is a leading cause of bacteremia and blood stream infections. Methicillin-resistant S. aureus (MRSA) that first appeared in 1961 often caused hospital-acquired infections (HAIs) and community-acquired infections (CAIs) and was associated with high mortality rate. Accurate and rapid point-of-care testing (POCT) of MRSA is crucial for clinical management and treatment of MRSA infections, as well as the prevention and control of HAIs and CAIs. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of methicillin-susceptible S. aureus and MRSA. The dual HiFi-LAMP assay can detect 30 copies/reaction of nuc and mecA genes with detection limits of 147 and 158 copies per 25 µL reaction, respectively. A retrospective clinical evaluation with 107 clinical S. aureus isolates showed both sensitivity and specificity of 100%. A prospective clinical evaluation with 35 clinical samples revealed a specificity of 100% and a sensitivity of 92.3%. The dual HiFi-LAMP assay can detect almost all S. aureus samples (141/142; 99.3%) within 20 min, implying that the entire HiFi-LAMP assay (including sample process) can be completed within 40 min, extremely significantly shorter than 3–5 days by the traditional clinical microbial culture and antibiotic susceptibility testing. The novel extraction-free dual HiFi-LAMP assay can be used as a robust POCT tool to promote precise diagnosis and treatment of MRSA infections in hospitals and to facilitate surveillance of MRSA at hospital and community settings. IMPORTANCE Methicillin-resistant Staphylococcus aureus (MRSA) was associated with high mortality rate and listed as a “priority pathogen” by the World Health Organization. Accurate and rapid point-of-care testing (POCT) of MRSA is critically required for clinical management and treatment of MRSA infections. Some previous LAMP-based POCT assays for MRSA might be questionable due to their low specificity and the lack of appropriate evaluation directly using clinical samples. Furthermore, they are relatively tedious and time-consuming because they require DNA extraction and lack multiplex detection capacity. Here, we reported a novel extraction-free dual HiFi-LAMP assay for discriminative detection of MRSA and methicillin-susceptible S. aureus . The assay has high specificity and sensitivity and can be completed within 40 min. Clinical evaluation with real clinical samples and clinical isolates showed excellent performance with 100% specificity and 92.3%–100% sensitivity. The novel extraction-free assay may be a robust POCT tool to promote precise diagnosis of MRSA infections and facilitate surveillance of MRSA at hospital and community settings.
23
Loop-mediated isothermal amplification of DNA
Tsugunori Notomi · Nucleic Acids Research · 2000 · 8.8K citations · Full text
Ilada Choopara, Akkapol Suea‐Ngam, Yothin Teethaisong et al. · ACS Sensors · 2021 · 95 citations
Omar H. Sheet, Nils Th. Grabowski, Günter Klein et al. · Molecular and Cellular Probes · 2016 · 73 citations
Veterinary Medicine, Microbiology, Veterinary Microbiology +15