Practical Laboratory Medicine · 2024 · 13 citations · 20 references
MedicineHematologyGood Laboratory PracticeHematopathologyMolecular DiagnosticsBioanalytical Method ValidationClinical AnalysisClinical HematologyInflammatory BiomarkersAnalytical Performance ModelingClinical Laboratory EvaluationComparative Assay EvaluationConfidence Intervals For Correlation CoefficientsCorrelationHigh-sensitivity AssaysLaboratory Test EvaluationWorkflow Automation
The new XR-Series haematology analyser from Sysmex provides increased throughput and automation, along with a new reagent in WDF channel for optimised WBC differential. An analytical performance study for the XR analyser was conducted to evaluate the WDF channel parameters in comparison to the instrument specifications. Additionally, 7460 samples were measured on XR and XN analysers to compare selected parameters and flags, and 930 randomly selected samples were further evaluated with microscopy. All investigated aspects of the analytical performance study for the XR fell within the manufacturer specifications. The correlation coefficients between the two systems for the parameters tested were greater than 0.983 for the main CBC and DIFF parameters, greater than 0.909 for the Extended Inflammation Parameters, and greater than 0.932 for the parameters used in the workflow rulesets of the Extended IPU. Similarly high sensitivities for the detection of abnormal cells were observed for the ‘Blasts/Abn Lympho?’ flag (XN: 100%, XR: 99.0%) and WPC abnormal flags (‘Blasts?’ or ‘Abn Lympho?‘) (XN: 97.0%, XR: 96.0%). XN with WPC channel had a 26% reduction of false positive smears compared to XR with 22% reduction, a statistically non-significant difference. The XR analyser had very good analytical performance, and highly comparable results to the predecessor XN analyser in all investigated parameters, flags and workflow aspects.
20
Performance evaluation of the Sysmex haematology XN modular system
Carol Briggs, Ian Longair, Punamar Kumar et al. · Journal of Clinical Pathology · 2012 · 187 citations
Mathias Bruegel, Dorothea Nagel, Manuela Funk et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2015 · 80 citations
Chérina Fleming, Rob Brouwer, Jan Lindemans et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2012 · 76 citations
Accuracy of a New Platelet Count System (PLT-F) Depends on the Staining Property of Its Reagents
Atsushi Wada, Yuri Takagi, Mari Kono et al. · PLoS ONE · 2015 · 58 citations · Full text
Medicine, Cell Biology, Hematology +17