Head & Neck · 2024 · 27 citations · 14 references
ComputingComputer ScienceSurgeryArtificial IntelligenceComputer VisionMachine LearningDeep LearningParathyroid ImagingParathyroid LocalizationParathyroid SurgeryPattern RecognitionThyroid SurgeryComputer-aided Thyroid DiagnosisEndoscopic Parathyroid ExplorationExternal Validation CohortsIntraoperative Parathyroid MappingOperative Success PredictionParathyroid Gland PreservationPreoperative Parathyroid ImagingPreoperative Parathyroid Localization
BACKGROUND: The preservation of parathyroid glands is crucial in endoscopic thyroid surgery to prevent hypocalcemia and related complications. However, current methods for identifying and protecting these glands have limitations. We propose a novel technique that has the potential to improve the safety and efficacy of endoscopic thyroid surgery. PURPOSE: Our study aims to develop a deep learning model called PTAIR 2.0 (Parathyroid gland Artificial Intelligence Recognition) to enhance parathyroid gland recognition during endoscopic thyroidectomy. We compare its performance against traditional surgeon-based identification methods. MATERIALS AND METHODS: Parathyroid tissues were annotated in 32 428 images extracted from 838 endoscopic thyroidectomy videos, forming the internal training cohort. An external validation cohort comprised 54 full-length videos. Six candidate algorithms were evaluated to select the optimal one. We assessed the model's performance in terms of initial recognition time, identification duration, and recognition rate and compared it with the performance of surgeons. RESULTS: Utilizing the YOLOX algorithm, we developed PTAIR 2.0, which demonstrated superior performance with an AP50 score of 92.1%. The YOLOX algorithm achieved a frame rate of 25.14 Hz, meeting real-time requirements. In the internal training cohort, PTAIR 2.0 achieved AP50 values of 94.1%, 98.9%, and 92.1% for parathyroid gland early prediction, identification, and ischemia alert, respectively. Additionally, in the external validation cohort, PTAIR outperformed both junior and senior surgeons in identifying and tracking parathyroid glands (p < 0.001). CONCLUSION: The AI-driven PTAIR 2.0 model significantly outperforms both senior and junior surgeons in parathyroid gland identification and ischemia alert during endoscopic thyroid surgery, offering potential for enhanced surgical precision and patient outcomes.
14
Accuracy of diagnosing invasive colorectal cancer using computer-aided endocytoscopy
Kenichi Takeda, Shin‐ei Kudo, Yuichi Mori et al. · Endoscopy · 2017 · 141 citations
A novel deep <scp>learning‐based</scp> method for detection of weeds in vegetables
Xiaojun Jin, Yanxia Sun, Jun Che et al. · Pest Management Science · 2022 · 116 citations
Autofluorescence imaging of parathyroid glands: An assessment of potential indications
Emin Köse, Anatoliy V. Rudin, Bora Kahramangil et al. · Surgery · 2019 · 107 citations
Medicine, Endocrinology, Radiology +16