Frontiers in Veterinary Science · 2024 · 11 citations · 17 references
Life SciencesVeterinary Clinical SciencesEquine MedicineEquine ScienceProteomicsClinical ProteomicsJoint DiseaseMass Spectrometry-based ProteomicsOsteoarthritisProteomic ProfilingBiomarkers Of Joint DegenerationMass Spectrometry ProteomicsMultiple Reaction MonitoringPlasma Protein AnalysisProinflammatory MediatorsProtein Mass SpectrometryQuantification Of AnalytesSelected Reaction Monitoring
Introduction Alpha 2 macroglobulin (A2M), a multi-functional protein in the plasma protease inhibitor class, regulates proinflammatory cytokines and the clearance of chondrodestructive enzymes in cases of joint injury and osteoarthritis (OA). The purpose of this study was to compare A2M concentrations in equine plasma samples processed by three commercial devices developed for stall-side regenerative joint therapy. Methods Plasma samples were obtained from healthy adult horses ( N = 13). Mass spectrometry analysis was used to determine the concentration of protein analytes in each sample. Selected reaction monitoring measured a specific A2M peptide as a surrogate of the whole A2M protein. A2M concentrations produced by each test device were compared for two sample types: a pre-concentrate or platelet-poor (PP) component and a final component for use in the horse. Results There was no significant difference ( p > 0.05) in the geometric mean (GM) concentration of A2M in the final concentration samples produced by the Alpha2EQ ® device (N horses = 13) and the single-centrifugation PP samples produced by the Pro-Stride ® APS (autologous protein solution) device ( N = 13) and the Restigen ® PRP (platelet-rich plasma) device ( N = 11). When A2M content in final concentration samples produced by each device was compared, the Pro-Stride APS and Restigen PRP samples had significantly greater GM A2M content ( p < 0.0001) compared to the Alpha2EQ samples, and the Pro-Stride APS final concentration samples had significantly greater GM A2M concentration ( p < 0.0001) versus that for the Restigen PRP final samples. Discussion This comparison demonstrated that the volume and A2M concentration of an Alpha2EQ final concentrate are no different than the volume and concentration of A2M in the PP from Pro-Stride or Restigen devices.
17
Absolute Quantification of Proteins by LCMSE
Jeffrey C. Silva, M. V. Gorenstein, Guozhong Li et al. · Molecular & Cellular Proteomics · 2005 · 1.6K citations · Full text
Aberrant repair and fibrosis development in skeletal muscle
Christopher J. Mann, Eusebio Perdiguero, Yacine Kharraz et al. · Skeletal Muscle · 2011 · 845 citations · Full text
Gerco Bosch, Hans T. M. van Schie, Mark W. de Groot et al. · Journal of Orthopaedic Research® · 2009 · 271 citations · Full text
Masahira Hattori, L J Abraham, W Northemann et al. · Proceedings of the National Academy of Sciences · 1990 · 178 citations