BMC Pulmonary Medicine · 2024 · 17 citations · 33 references
Health ProfessionsRespiratory TherapyPulmonologyVentilationVentilator ManagementAirway SupportBreathing SupportMechanical VentilationPositive End-expiratory PressureRespiratory Failure ManagementAcute Hypoxemic Respiratory FailureHigh-flow Nasal Cannula Oxygen TherapyHigh-flow Nasal Cannula SupportHigh-flow Oxygen TherapyPost-extubation Respiratory SupportRespiratory Dead SpaceRespiratory Gas ExchangeVenturi Mask Therapy
BACKGROUND: Standard high-flow nasal cannula (HFNC) is a respiratory support device widely used to manage post-extubation hypoxemic acute respiratory failure (hARF) due to greater comfort, oxygenation, alveolar recruitment, humidification, and reduction of dead space, as compared to conventional oxygen therapy. On the contrary, the effects of the new asymmetrical HFNC interface (Optiflow® Duet system (Fisher & Paykel, Healthcare, Auckland, New Zealand) is still under discussion. Our aim is investigating whether the use of asymmetrical HFNC interface presents any relevant difference, compared with the standard configuration, on lung aeration (as assessed by end-expiratory lung impedance (EELI) measured by electrical impedance tomography (EIT)), diaphragm ultrasound thickening fraction (TFdi) and excursion (DE), ventilatory efficiency (estimated by corrected minute ventilation (MV)), gas exchange, dyspnea, and comfort. METHODS: < 300 mmHg during Venturi mask (VM) within 120 min after extubation. Each HFNC configuration was applied in a randomized 60 min sequence at a flow rate of 60 L/min. RESULTS: Global EELI, TFdi, DE, ventilatory efficiency, gas exchange and dyspnea were not significantly different, while comfort was greater during asymmetrical HFNC support, as compared to standard interface (10 [7-10] and 8 [7-9], p-value 0.044). CONCLUSIONS: In post-extubation hARF, the use of the asymmetrical HFNC, as compared to standard HFNC interface, slightly improved patient comfort without affecting lung aeration, diaphragm activity, ventilatory efficiency, dyspnea and gas exchange. CLINICAL TRIAL NUMBER: ClinicalTrial.gov. REGISTRATION NUMBER: NCT05838326 (01/05/2023). NEW & NOTEWORTHY: The asymmetrical high-flow nasal cannula oxygen therapy (Optiflow® Duet system (Fisher & Paykel, Healthcare, Auckland, New Zealand) provides greater comfort as compared to standard interface; while their performance in term of lung aeration, diaphragm activity, ventilatory efficiency, dyspnea, and gas exchange is similar.
33
Weaning from mechanical ventilation
J-M. Boles, Julian Bion, Alfred F. Connors et al. · European Respiratory Journal · 2007 · 2.1K citations · Full text
Health Professions, Respiratory Therapy, Perioperative Critical Care +11
Salvatore Maurizio Maggiore, Francesco Idone, Rosanna Vaschetto et al. · American Journal of Respiratory and Critical Care Medicine · 2014 · 547 citations
Medicine, Respiratory Therapy, Pulmonary Function Testing +16
Martin Dres, Bruno‐Pierre Dubé, Julien Mayaux et al. · American Journal of Respiratory and Critical Care Medicine · 2016 · 545 citations · Full text
Health Professions, Physiology, Critical Care Respiratory Therapy +16