American Journal of Respiratory and Critical Care Medicine · 2016 · 545 citations · 29 references
Health ProfessionsPhysiologyCritical Care Respiratory TherapyPulmonary Function TestingVentilator ManagementAcute Respiratory Distress Syndrome VentilationBreathing SupportMechanical VentilationMuscle Strength AssessmentMuscle Strength TestingVentilatory SupportDiaphragm DysfunctionDiaphragmatic Dysfunction AssessmentDiaphragmatic WeaknessIntensive Care Unit Acquired WeaknessLimb Weakness AssessmentMechanical Ventilation LiberationVentilator-associated Acquired WeaknessVentilator-induced Diaphragm Dysfunction
RATIONALE: Intensive care unit (ICU)- and mechanical ventilation (MV)-acquired limb muscle and diaphragm dysfunction may both be associated with longer length of stay and worse outcome. Whether they are two aspects of the same entity or have a different prevalence and prognostic impact remains unclear. OBJECTIVES: To quantify the prevalence and coexistence of these two forms of ICU-acquired weakness and their impact on outcome. METHODS: O defined dysfunction) and ultrasonography (thickening fraction [TFdi] and excursion). Limb muscle weakness was defined as a Medical Research Council (MRC) score less than 48. MEASUREMENTS AND MAIN RESULTS: Seventy-six patients were assessed at their first spontaneous breathing trial: 63% had diaphragm dysfunction, 34% had limb muscle weakness, and 21% had both. There was a significant but weak correlation between MRC score and twitch pressure (ρ = 0.26; P = 0.03) and TFdi (ρ = 0.28; P = 0.01), respectively. Low twitch pressure (odds ratio, 0.60; 95% confidence interval, 0.45-0.79; P < 0.001) and TFdi (odds ratio, 0.84; 95% confidence interval, 0.76-0.92; P < 0.001) were independently associated with weaning failure, but the MRC score was not. Diaphragm dysfunction was associated with higher ICU and hospital mortality, and limb muscle weakness was associated with longer duration of MV and hospital stay. CONCLUSIONS: Diaphragm dysfunction is twice as frequent as limb muscle weakness and has a direct negative impact on weaning outcome. The two types of muscle weakness have only limited overlap.
29
Weaning from mechanical ventilation
J-M. Boles, Julian Bion, Alfred F. Connors et al. · European Respiratory Journal · 2007 · 2.1K citations · Full text
Health Professions, Respiratory Therapy, Perioperative Critical Care +11
Rapid Disuse Atrophy of Diaphragm Fibers in Mechanically Ventilated Humans
Sanford Levine, Taitan Nguyen, Nyali Taylor et al. · New England Journal of Medicine · 2008 · 1.6K citations · Full text
Life Sciences, Anatomy, Physiology +16