Nuclear Fusion · 2023 · 16 citations · 13 references
Natural SciencesNuclear EngineeringPhysicsFusion EngineeringNuclear InstrumentationPlasma PhysicsFusion PlasmasMagnetic Confinement FusionMagnetized PlasmaNeutral Beam InjectionNuclear FusionPlasma ConfinementHeating Of Tokamak PlasmasMagnetic Flux ConsumptionNeutral Beam Injection HeatingPlasma ComponentsPlasma Facing ComponentsTokamak EquilibriumTokamak Plasmas
Abstract High-performance long-pulse plasma operation is essential for producing economically viable fusion energy in tokamak devices. To achieve such discharges in KSTAR, firstly, the rapid increase in the temperature of plasma-facing components was mitigated. The temperature increase of the poloidal limiter, especially, was associated with beam-driven fast ion orbit loss and the discrepancy of the equilibrium reconstructed with heated magnetic probes of signal drift. The fast ions lost to the poloidal limiter were reduced by optimizing the plasma shape and the composition of neutral beam injection (NBI). This nonlinear signal drift was successfully reduced by a new thermal shielding protector on the magnetic probes. Secondly, a lower loop voltage approach was implemented to reduce a poloidal flux consumption rate. A plasma current of 400 kA and a line-averaged electron density of ∼2.0 × 10 19 m −3 were chosen by considering the L – H power threshold, fast ion orbit loss, and beam shine-through power loss for low loop voltage in KSTAR. In addition, the application of electron cyclotron heating also helped maintain the plasma with low loop voltage (∼25 mV) by enhancing the NBI-driven current and achieving a high poloidal beta ( β P ) state. KSTAR has achieved a long pulse (∼90 s) operation with the high performance of β P ⩽ 2.7, thermal energy confinement enhancement factor (H 98y2 ) ∼ 1.1, and fraction of non-inductive current ( f NI ) ⩽ 0.96. Still, gradual degradation of the plasma performance has been observed over time in the discharges. In one of the long-pulse discharges, β P reduced by ∼18% over the time of ∼8 τ R (current relaxation time, τ R ∼ 5 s) and ∼1067 τ E,th (thermal energy confinement time, τ E,th ∼ 45 ms). The degradation may be closely associated with weak, yet growing, and persistent toroidal Alfvén eigenmodes and their effect on fast ion confinement.
13
Chapter 6: Steady state operation
C. Gormezano, A. C. C. Sips, T. C. Luce et al. · Nuclear Fusion · 2007 · 380 citations
Natural Sciences, Nuclear Engineering, Fusion Engineering +16
Realization of thousand-second improved confinement plasma with Super I-mode in Tokamak EAST
Yuntao Song, X. L. Zou, Xianzu Gong et al. · Science Advances · 2023 · 108 citations · Full text