EJNMMI Physics · 2023 · 22 citations · 44 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAttenuation CorrectionComputed TomographyImage ReconstructionMedical ImagingNuclear Medicine ImagingScatter CorrectionActivity QuantificationAttenuation-corrected ReconstructionComputed Tomography PhantomsIterative Scatter CorrectionOptimization Of Scan ParametersPoint Spread FunctionPoint Spread Function EstimationScatter Correction Algorithms
Abstract Background The aim of this study was to investigate the quantification performance of a 360° CZT camera for 177 Lu-based treatment monitoring. Methods Three phantoms with known 177 Lu activity concentrations were acquired: (1) a uniform cylindrical phantom for calibration, (2) a NEMA IEC body phantom for analysis of different-sized spheres to optimise quantification parameters and (3) a phantom containing two large vials simulating organs at risk for tests. Four sets of reconstruction parameters were tested: (1) Scatter, (2) Scatter and Point Spread Function Recovery (PSFR), (3) PSFR only and (4) Penalised likelihood option and Scatter, varying the number of updates (iterations × subsets) with CT-based attenuation correction only. For each, activity concentration (ARC) and contrast recovery coefficients (CRC) were estimated as well as root mean square. Visualisation and quantification parameters were applied to reconstructed patient image data. Results Optimised quantification parameters were determined to be: CT-based attenuation correction, scatter correction, 12 iterations, 8 subsets and no filter. ARC, CRC and RMS results were dependant on the methodology used for calculations. Two different reconstruction parameters were recommended for visualisation and for quantification. 3D whole-body SPECT images were acquired and reconstructed for 177 Lu-PSMA patients in 2–3 times faster than the time taken for a conventional gamma camera. Conclusion Quantification of whole-body 3D images of patients treated with 177 Lu-PSMA is feasible and an optimised set of parameters has been determined. This camera greatly reduces procedure time for whole-body SPECT.
44
Lutetium-177–PSMA-617 for Metastatic Castration-Resistant Prostate Cancer
Oliver Sartor, Johann S. de Bono, Kim N. et al. · New England Journal of Medicine · 2021 · 2.6K citations · Full text
John Violet, Price Jackson, Justin Ferdinandus et al. · Journal of Nuclear Medicine · 2018 · 486 citations · Full text
Medicine, Nuclear Medicine, Oncology +17