Clinical Chemistry and Laboratory Medicine (CCLM) · 2023 · 23 citations · 23 references
Life SciencesNeurologyNeuroscienceClinical NeuroscienceNeuroimmunologyNeuropathologyAutoimmune BiomarkersBioanalytical Method ValidationBiomarkers Of NeurodegenerationCerebrospinal Fluid BiomarkersMultiple SclerosisNeuroinflammationAxonal Damage BiomarkersAxonal Injury BiomarkersImmunoassay MethodologyLower Limit Of QuantificationLower Limit Of QuantitationNeurofilament BiomarkersNeuronal Injury BiomarkersSensitivity
OBJECTIVES: Neurofilament light chain (NfL) has emerged as a promising biomarker for detecting and monitoring axonal injury. Until recently, NfL could only be reliably measured in cerebrospinal fluid, but digital single molecule array (Simoa) technology has enabled its precise measurement in blood samples where it is typically 50-100 times less abundant. We report development and multi-center validation of a novel fully automated digital immunoassay for NfL in serum for informing axonal injury status. METHODS: A 45-min immunoassay for serum NfL was developed for use on an automated digital analyzer based on Simoa technology. The analytical performance (sensitivity, precision, reproducibility, linearity, sample type) was characterized and then cross validated across 17 laboratories in 10 countries. Analytical performance for clinical NfL measurement was examined in individual patients with relapsing remitting multiple sclerosis (RRMS) after 3 months of disease modifying treatment (DMT) with fingolimod. RESULTS: The assay exhibited a lower limit of detection (LLoD) of 0.05 ng/L, a lower limit of quantification (LLoQ) of 0.8 ng/L, and between-laboratory imprecision <10 % across 17 validation sites. All tested samples had measurable NfL concentrations well above the LLoQ. In matched pre-post treatment samples, decreases in NfL were observed in 26/29 RRMS patients three months after DMT start, with significant decreases detected in a majority of patients. CONCLUSIONS: The sensitivity characteristics and reproducible performance across laboratories combined with full automation make this assay suitable for clinical use for NfL assessment, monitoring in individual patients, and cross-comparisons of results across multiple sites.
23
Serum Neurofilament light: A biomarker of neuronal damage in multiple sclerosis
Giulio Disanto, Christian Barro, Pascal Benkert et al. · Annals of Neurology · 2017 · 1.2K citations · Full text
Diagnostic Value of Cerebrospinal Fluid Neurofilament Light Protein in Neurology
Claire Bridel, Wessel N. van Wieringen, Henrik Zetterberg et al. · JAMA Neurology · 2019 · 760 citations · Full text